datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:arete_arix A3000 slotfn Feb88

arete_arix A3000 slotfn Feb88 free download

Various electronics service manuals

File information:
File name:A3000_slotfn_Feb88.pdf
[preview A3000 slotfn Feb88]
Size:175 kB
Extension:pdf
Mfg:arete_arix
Model:A3000 slotfn Feb88 🔎
Original:A3000 slotfn Feb88 🔎
Descr: . Rare and Ancient Equipment arete_arix a3000 A3000_slotfn_Feb88.pdf
Group:Electronics > Other
Uploaded:08-06-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name A3000_slotfn_Feb88.pdf

Feb 10 11:01 1988 slotfn.h Page 1 This describes the appearance of the processor module as seen by other modules on the CSS bus. Read status Register: An automatic register may be read (byte or long) at physical address offset:Oxfffffffc. The register is "automatic" because it responds without assistance from the processor. 31-------------24 23---------21 20 19 18--16 15-------8 7-------------0 +----------------+--------------+----+----+------+----------+-----------------+ I I I cmd I (board id) I I unpredictable lipl2 ipl1 iplO halt pend 1 1 1 I mail reg I 0 0 0 0 0 0 1 0 I +----------------+--------------+----+----+------+----------+-----------------+ ipl2,1,0 reflect the (low true) value at the processor input halt=O indicates the processor has a double bus error cmd-pend=l indicates the command buffer is full mail reg is loaded by the processor at BUS MAIL BYTE. Command register: Commands to read or write are accepted at offset:Ox??????OO (where? represents 4 don't care bits), as required by the CS8 Bus Specification. The register captures four bytes of address and four bytes of data. The data captured from a read command is not predictable. Receiving a command, except the automatic read, causes a Non-Maskable Interrupt to be asserted at the processor, and the cmd-pend bit to be set. The processor's firmware is expected to respond to the command. Further commands cannot be received until the processor increments its ready-count on the arbiter. HARDWARE LIMITATIONS: Since the equipment for sending DATA RESPONSEs is not usable while the processor is executing from main memory or testing cache or mmu, read commands are not recommended as part of the normal protocol. Also, the type value is not captured, so the module has no easy way to tell an arriving read from a write command. I.t- '1\ l--\ r . \. Feb 10 11:01 1988 slotfn.h Page 2 l 1_._".,,_...

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
arete_arix Asynchronous Communications Interface Adapter Spec May88 - arete_arix System Bus Specification Feb88 - arete_arix IP-07458-00 OS90 Installation Guide and Release Notes Release 3.3 Jan92 - arete_arix IP-07685-00 OS90 Supplemental Software Release 2 May92 - arete_arix CSS Bus Spec - arete_arix MA-99387-00 System90 Model 45 85 Site Preparation Manual Jan90 - arete_arix System 3000 Memory Module -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : DYNACORD 29871d1407078983- -powermate-1000

script execution: 0.01 s